CES-A-C5H-01 Euchner 091458
 CES-A-C5H-01 Euchner 091458

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.

Euchner CES-A-C5H-01 091458

Manufacturer

Euchner

Country

Germany

Name

CES-A-C5H-01

Part number

091458

Description

SICHERHEITSSCHALTER UNICODE CES-A-C5H-01

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications CES-A-C5H-01 091458

Call us to get a great deal on Euchner 091458. We supply only new equipment Euchner directly from the manufacturer, therefore we can offer the most advantageous cost and a quality guarantee. FAMAGA sells only certified industrial equipment and gives an official guarantee from the fabricator Euchner.

Our employees speak your language. In a short time they will find for you Euchner at the best value, will select any for you spare parts and accessories for Euchner 091458, will recommend counterparts and agree delivery time to the doors of your company.

Perfect system of delivery allows us to deliver equipment to any city in South Africa or any other destination point in the world that you will choose in a short time . If you become our constant client, you will get special, even more attractive terms of cooperation.

Our company has been working in South Africa for over eight years, supplying equipment to over 1700 clients worldwide. Among our clients are over 2600 large companies with world names.

If extra information is needed please contact us, send your request to our E-mail.

Features CES-A-C5H-01 091458

  • Safety switch with integrated evaluation electronics
  • Possible to switch pulsed signals
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Unicode
Approach directionCan be adjusted in 90° steps Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in. Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN ISO 13849-1
LED indicator
STATEStatus LED
OUT/ERRORSafety outputs status / diagnostics LED (combined)
Additional connection
OUTMonitoring output (semiconductor)
Attention:The operating distance may vary depending on the background material and installation situation. (Only in combination with actuator CES-A-BBA, CES-A-BCA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the operating distance of the side lobes is not entered. (Only in combination with actuator CES-A-BPA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered.
Dimensions According to EN 60947-5-2: (LxWxH) 131x40x40
Housing material Plastic, PBT
Weight
Net 0,4 kg
Ambient temperature
At UB = 24 V DC -20 ... 55 °C
Degree of protection IP67
Mounting distance
Between 2 read heads or 2 actuators min.80 mm
Installation orientation Any
Tightening torque
Screws fastening bracket read head max.0,6 Nm
Fixing screws housing max.1 Nm
Ready delay max.3 s
Reaction time
After change in the actuation status max.180 ms
Switching frequency max.1 Hz
Dwell time min.0,5 s
Connection M12 plug connector, 8-pin, screen can be applied
Electrical connection ratings
Operating voltage DC 18 ... 24 ... 27 V DC Regulated, residual ripple < 5 %
Current consumption 80 mA
Fusing
(External) operating voltage 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs LA / LB
Type of output Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled
Output voltage
HIGH U(LA) U(+LA) - 1,5 ... U(+LA) V DC
HIGH U(LB) U(+LB) - 1,5 ... U(+LB) V DC
LOW U(LA) / U(LB) 0 ... 1 V DC
Output current
per safety output 1 ... 400 mA
Fusing
External, safety circuit U(+LA) / U(+LB) 0.4 A medium slow-blow
Utilization category according to EN 60947-5-2
DC-13 24V 400mA
Switching load
According to UL max. DC 24 V, class 2
Rated conditional short-circuit current max.100 A
Discrepancy time
(Between the operating points of both safety outputs) max.120 ms
Power supply output load
U(+LA) / U(+LB) 24 V DC 18 ... 27 V DC
Monitoring output OUT
Type of output Semiconductor output, p-switching, short circuit-proof
Output voltage 0,8 x UB ... UB V DC
Output current max.20 mA
STATE LED
LED indicator Status - LED
LED OUT / ERROR
LED indicator Safety outputs status / diagnostics (combined)
Work area
Repeat accuracy R max.10 %
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Diagnostic Coverage (DC) 99 %
Mission time 20 y
In combination with Actuator CES-A-BPAOperating distance
Distance s, actuator
Minimum distance for side approach direction min.6 mm
Switch-on distance
With center offset m=0 22 mm
Assured switch-off distance Sar max.58 mm
Assured operating distance Sao
With center offset m=0 min.15 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDA-20Operating distance
Distance s, actuator
Minimum distance for side approach direction min.5 mm
Switch-on distance
With center offset m=0 21 mm
Assured switch-off distance Sar max.41 mm
Assured operating distance Sao
With center offset m=0 min.19 mm
Switching hysteresis min.2 mm
In combination with Actuator CES-A-BBA, CES-A-BCAOperating distance
Distance s, actuator
Minimum distance for side approach direction min.4 mm
Switch-on distance
With center offset m=0 20 mm
Assured switch-off distance Sar max.40 mm
Assured operating distance Sao
With center offset m=0 min.18 mm
Switching hysteresis min.2 mm