We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CES-A-C5H-01
Part number
091458
Description
SICHERHEITSSCHALTER UNICODE CES-A-C5H-01
Stock availability:
On request
Call us to get a great deal on Euchner 091458. We supply only new equipment Euchner directly from the manufacturer, therefore we can offer the most advantageous cost and a quality guarantee. FAMAGA sells only certified industrial equipment and gives an official guarantee from the fabricator Euchner.
Our employees speak your language. In a short time they will find for you Euchner at the best value, will select any for you spare parts and accessories for Euchner 091458, will recommend counterparts and agree delivery time to the doors of your company.
Perfect system of delivery allows us to deliver equipment to any city in South Africa or any other destination point in the world that you will choose in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Tonga, Jordan, Indonesia, Nigeria, Barbados, Brazil, Greece, Eswatini, Burkina Faso, Liberia, Finland, Philippines, Palestine, Mauritania, United States, Armenia, Brunei, Yemen, Germany, Côte d\'Ivoire, Suriname, Morocco, Pakistan, Algeria, Lesotho, Uganda, Israel, Norway, Seychelles, Kuwait, Croatia, Laos, Andorra, Senegal, Jamaica, El Salvador, Singapore, Malta, Papua New Guinea, Bahrain, Uruguay, Moldova, Canada, Romania, Guinea, Cuba, Sweden, Tunisia. If you become our constant client, you will get special, even more attractive terms of cooperation.
Our company has been working in South Africa for over eight years, supplying equipment to over 1700 clients worldwide. Among our clients are over 2600 large companies with world names.
If extra information is needed please contact us, send your request to our E-mail.
STATE | Status LED |
OUT/ERROR | Safety outputs status / diagnostics LED (combined) |
OUT | Monitoring output (semiconductor) |
Dimensions | According to EN 60947-5-2: (LxWxH) 131x40x40 |
Housing material | Plastic, PBT |
Weight | |
Net | 0,4 kg |
Ambient temperature | |
At UB = 24 V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Mounting distance | |
Between 2 read heads or 2 actuators | min.80 mm |
Installation orientation | Any |
Tightening torque | |
Screws fastening bracket read head | max.0,6 Nm |
Fixing screws housing | max.1 Nm |
Ready delay | max.3 s |
Reaction time | |
After change in the actuation status | max.180 ms |
Switching frequency | max.1 Hz |
Dwell time | min.0,5 s |
Connection | M12 plug connector, 8-pin, screen can be applied |
Operating voltage DC | 18 ... 24 ... 27 V DC Regulated, residual ripple < 5 % |
Current consumption | 80 mA |
Fusing | |
(External) operating voltage | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety outputs LA / LB | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled |
Output voltage | |
HIGH U(LA) | U(+LA) - 1,5 ... U(+LA) V DC |
HIGH U(LB) | U(+LB) - 1,5 ... U(+LB) V DC |
LOW U(LA) / U(LB) | 0 ... 1 V DC |
Output current | |
per safety output | 1 ... 400 mA |
Fusing | |
External, safety circuit U(+LA) / U(+LB) | 0.4 A medium slow-blow |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 400mA |
Switching load | |
According to UL | max. DC 24 V, class 2 |
Rated conditional short-circuit current | max.100 A |
Discrepancy time | |
(Between the operating points of both safety outputs) | max.120 ms |
Power supply output load | |
U(+LA) / U(+LB) | 24 V DC 18 ... 27 V DC |
Monitoring output OUT | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0,8 x UB ... UB V DC |
Output current | max.20 mA |
STATE LED | |
LED indicator | Status - LED |
LED OUT / ERROR | |
LED indicator | Safety outputs status / diagnostics (combined) |
Repeat accuracy R | max.10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Monitoring of the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Diagnostic Coverage (DC) | 99 % |
Mission time | 20 y |
Distance s, actuator | |
Minimum distance for side approach direction | min.6 mm |
Switch-on distance | |
With center offset m=0 | 22 mm |
Assured switch-off distance Sar | max.58 mm |
Assured operating distance Sao | |
With center offset m=0 | min.15 mm |
Switching hysteresis | min.1 mm |
Distance s, actuator | |
Minimum distance for side approach direction | min.5 mm |
Switch-on distance | |
With center offset m=0 | 21 mm |
Assured switch-off distance Sar | max.41 mm |
Assured operating distance Sao | |
With center offset m=0 | min.19 mm |
Switching hysteresis | min.2 mm |
Distance s, actuator | |
Minimum distance for side approach direction | min.4 mm |
Switch-on distance | |
With center offset m=0 | 20 mm |
Assured switch-off distance Sar | max.40 mm |
Assured operating distance Sao | |
With center offset m=0 | min.18 mm |
Switching hysteresis | min.2 mm |