MGB-L2-ARA-AA1A1-M-104303 Euchner 104303
 MGB-L2-ARA-AA1A1-M-104303 Euchner 104303

We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.

Euchner MGB-L2-ARA-AA1A1-M-104303 104303

Manufacturer

Euchner

Country

Germany

Name

MGB-L2-ARA-AA1A1-M-104303

Part number

104303

Description

Verriegelungsgehäuse Sicherheit

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications MGB-L2-ARA-AA1A1-M-104303 104303

Call us to get a great deal on Euchner 104303. We supply only new goods Euchner directly from the manufacturer, therefore we can offer the best price and a quality guarantee. FAMAGA sells only certified equipment and gives an official guarantee from the producer Euchner.

Our employees speak your language. In a short time they will find for you Euchner at the best value, find your desirable spare parts and accessories for Euchner 104303, will recommend counterparts and agree delivery terms to the doors of your company.

Well-functioning logistics system allows us to send goods to any city in South Africa or any point of the world for the delivery chosen by you in a short time . If you become our constant buyer, you will get the most satisfying terms for future cooperation.

Our company has been working in South Africa for over ten years, supplying goods to over 18500 clients around the globe. The list of our clients includes over 2500 large companies with world names.

If extra information is needed please contact us, send your request to our E-mail.

Features MGB-L2-ARA-AA1A1-M-104303 104303

  • Guard locking with guard lock monitoring
  • Can be connected in series with other AR devices (e.g. CES-AR and CET-AR)
  • With cable entry
  • Unicode
Guard locking type
MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked).
Door hingeA mechanical door stop is permanently integrated into the evaluation module of the MGB. A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Monitoring outputs
ODON when the door is closed
OTBolt tongue inserted in the evaluation module
OLGuard locking solenoid in locked position
OIDiagnostics, there is a fault
Dimension drawing Cable entry MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Changing single wiring (AP) to series wiring (AR) MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawingCable entry Technical dataApprovals Mechanical values and environment
Housing material Reinforced plastic, die-cast zinc nickel-plated, stainless steel
Weight
Net 0,75 kg
Ambient temperature
At UB = 24V DC -20 ... 55 °C
Degree of protection IP65
Mechanical life 1 x 106
In case of use as door stop, and 1 Joule impact energy 0,1 x 106
Installation orientation Any
Switching frequency 0,25 Hz
Connection Cable entries M20x1.5
Guard locking principle Open-circuit current principle
Locking force FZh 2000 N
Electrical connection ratings
Utilization category according to EN 60947-5-2
DC-13 24V 200mA
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1,5 kV
Degree of contamination (external, according to EN 60947-1) 3
Connection cross-section
(Rigid/flexible) 0,13 ... 1,5 mm? (AWG 24 ... AWG 16)
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 0,25 ... 1,5 mm?
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 0,25 ... 0,75 mm?
Safety class III
Discrepancy time
Between FO1A and FO1B max.10 ms
Risk time according to EN 60947-5-3 max.350 ms
Transponder coding Unicode
Power supply UB
Operating voltage DC
UB 24 V DC -15% ... 10%
Current consumption
IUB max.80 mA
Power supply UA
Operating voltage DC
UA 24 V DC -15% ... 10%
Current consumption
IUA max.375 mA
Safety outputs FO1A, FO1B
Test pulses max.1 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage
UFO1A /UFO1B HIGH UB-2V ... UB V DC
UFO1A /UFO1B LOW 0 ... 1 V DC
Output current
Per safety output FO1A / FO1B 1 ... 200 mA
Monitoring outputs OD, OT, OL, OI
Type of output Semiconductor outputs, p-switching, short circuit-proof
Output voltage UA-2V ... UA V DC
Output current max.50 mA
Solenoid control input IMP1, IMP2, IMM
Test pulses max.5 ms
Test-pulse interval min.100 ms
Other
Product version number V3.0.3
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
Category 4
Performance Level PL e
PFHD 3.7 x 10-9
Mission time 20 y