We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
MGB-L2-ARA-AA1A1-M-104303
Part number
104303
Description
Verriegelungsgehäuse Sicherheit
Stock availability:
On request
Call us to get a great deal on Euchner 104303. We supply only new goods Euchner directly from the manufacturer, therefore we can offer the best price and a quality guarantee. FAMAGA sells only certified equipment and gives an official guarantee from the producer Euchner.
Our employees speak your language. In a short time they will find for you Euchner at the best value, find your desirable spare parts and accessories for Euchner 104303, will recommend counterparts and agree delivery terms to the doors of your company.
Well-functioning logistics system allows us to send goods to any city in South Africa or any point of the world for the delivery chosen by you in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Equatorial Guinea, Seychelles, Slovakia, Peru, Pakistan, Kenya, Armenia, East Timor, Philippines, Tonga, Brazil, Argentina, Bahrain, Serbia, Greece, Germany, Iran, South Korea, Kyrgyzstan, Senegal, Romania, Palestine, Congo, Benin, Guinea, Denmark, Mauritania, Bosnia and Herzegovina, Uruguay, Switzerland, Dominica, Yemen, Kuwait, Tunisia, Antigua and Barbuda, Malaysia, New Zealand, Papua New Guinea, San Marino, Russia, Lesotho, United Arab Emirates, Moldova, Paraguay, Niger, Gabon, United States. If you become our constant buyer, you will get the most satisfying terms for future cooperation.
Our company has been working in South Africa for over ten years, supplying goods to over 18500 clients around the globe. The list of our clients includes over 2500 large companies with world names.
If extra information is needed please contact us, send your request to our E-mail.
MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked). |
OD | ON when the door is closed |
OT | Bolt tongue inserted in the evaluation module |
OL | Guard locking solenoid in locked position |
OI | Diagnostics, there is a fault |
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 0,75 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Any |
Switching frequency | 0,25 Hz |
Connection | Cable entries M20x1.5 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connection cross-section | |
(Rigid/flexible) | 0,13 ... 1,5 mm? (AWG 24 ... AWG 16) |
(Rigid/flexible) with cable end sleeve according to DIN 46 228/1 | 0,25 ... 1,5 mm? |
(Rigid/flexible) with cable end sleeve with collar according to DIN 46 228/1 | 0,25 ... 0,75 mm? |
Safety class | III |
Discrepancy time | |
Between FO1A and FO1B | max.10 ms |
Risk time according to EN 60947-5-3 | max.350 ms |
Transponder coding | Unicode |
Power supply UB | |
Operating voltage DC | |
UB | 24 V DC -15% ... 10% |
Current consumption | |
IUB | max.80 mA |
Power supply UA | |
Operating voltage DC | |
UA | 24 V DC -15% ... 10% |
Current consumption | |
IUA | max.375 mA |
Safety outputs FO1A, FO1B | |
Test pulses | max.1 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
UFO1A /UFO1B HIGH | UB-2V ... UB V DC |
UFO1A /UFO1B LOW | 0 ... 1 V DC |
Output current | |
Per safety output FO1A / FO1B | 1 ... 200 mA |
Monitoring outputs OD, OT, OL, OI | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | UA-2V ... UA V DC |
Output current | max.50 mA |
Solenoid control input IMP1, IMP2, IMM | |
Test pulses | max.5 ms |
Test-pulse interval | min.100 ms |
Product version number | V3.0.3 |
Monitoring of guard locking and the safety guard position | |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Mission time | 20 y |