We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Contact us to get a great deal on IFM Magnetic-inductive flow meter SM8000. We supply only new industrial machinery IFM directly from the manufacturer, therefore we can offer the most attractive price and a quality guarantee. FAMAGA sells only certified products and gives an official guarantee from the manufacturer IFM.
Our highly-qualified workers speak your language. In a short time they will find for you IFM Magnetic-inductive flow meter at the best value, will select any for you spare parts and accessories for IFM Magnetic-inductive flow meter SM8000, will recommend counterparts and agree delivery timings to the doors of your company.
Impressive shipping system allows us to deliver industrial machinery to any city in South Africa or any point of the world for the delivery chosen by you in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Afghanistan, Belgium, Guinea-Bissau, Romania, Monaco, Jamaica, China, Georgia, Lebanon, Azerbaijan, Cameroon, Belarus, Italy, Andorra, Yemen, Switzerland, Gabon, Ethiopia, Cape Verde, Armenia, South Sudan, Gambia, The Bahamas, New Zealand, Pakistan, Congo, Eritrea, Mauritania, Paraguay, Kiribati, Rwanda, Algeria, Thailand, Canada, Philippines, Bangladesh, The Gambia, Bahamas, Venezuela, Poland, Central African Republic, India, Malta, Morocco. If you become our constant client, you will get special, even more attractive terms of cooperation.
Our enterprise has been working in South Africa for over eight years, supplying industrial machinery to over 1700 clients all over the earth. The list of our clients includes over 2600 large companies with world names.
For terms of cooperation please contact us, send your request to our E-mail.
Application | |||||||||
---|---|---|---|---|---|---|---|---|---|
Application | Sum function, for general industrial use | ||||||||
Installation | pipe connection with adapter | ||||||||
Medium | Conductive liquids, Water, water-based liquids | ||||||||
Medium note |
| ||||||||
Measured medium temperature [°C] | -10…70 | ||||||||
Pressure strength [bar] | 16 | ||||||||
MAWP (for use according to CRN) [bar] | 11.2 | ||||||||
Electronic data | |||||||||
Operating voltage [V] | 18…30 DC, (according to EN 50178 SELV/PELV ) | ||||||||
Current consumption [mA] | 95, (24 V) | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Power-on delay time [s] | 5 | ||||||||
Inputs/outputs | |||||||||
Number of inputs and outputs | Number of digital outputs: 2, Number of analog outputs: 1 | ||||||||
Inputs | |||||||||
Inputs | reset counter | ||||||||
Outputs | |||||||||
Total number of outputs | 2 | ||||||||
Output signal | Switching signal analog New signal, pulse signal, IO-Link, (configurable) | ||||||||
Electrical version | PNP/NPN | ||||||||
Number of digital outputs | 2 | ||||||||
Output signal function | normally open / normally closed, (parameterizable) | ||||||||
Max. voltage drop DC switching output [V] | 2 | ||||||||
DC switching output load current [mA] | 200 | ||||||||
Number of analog outputs | 1 | ||||||||
Analog current output [mA] | 4…20, (scalable) | ||||||||
Max. load [?] | 500 | ||||||||
Analog voltage output [V] | 0…10, (scalable) | ||||||||
Min. load resistance [?] | 2000 | ||||||||
Pulse output | Flowmeter | ||||||||
Short-circuit protection | yes | ||||||||
Short-circuit protection type | clocked | ||||||||
Overcurrent protection | yes | ||||||||
Measurement/setting range | |||||||||
Range measurements |
| ||||||||
Display range |
| ||||||||
Resolution |
| ||||||||
Setting point SP |
| ||||||||
Reset point rP |
| ||||||||
The starting point of the analog signal, ASP |
| ||||||||
Analogue end point, AEP |
| ||||||||
Width step |
| ||||||||
Momentary flow control | |||||||||
Pulse value | 0.00001 …100 000 m? | ||||||||
Pulse length [s] | 0.0025…2 | ||||||||
Temperature control | |||||||||
Measuring range [°C] | -20…80 | ||||||||
Resolution [°C] | 0.2 | ||||||||
Setting point SP [°C] | -19.2…80 | ||||||||
Reset point rP [°C] | -19.6…79.6 | ||||||||
Analog start point [°C] | -20…60 | ||||||||
Analogue end point [°C] | 0…80 | 0…80 | |||||||
In steps of [°C] | 0.2 | ||||||||
Accuracy/Uncertainty | |||||||||
Flow rate control | |||||||||
Accuracy (in measuring range) | ± (0.8 % MW + 0.5% MEW) | ||||||||
Repeatability | ± 0.2% MEW | ||||||||
Temperature control | |||||||||
Accuracy [K] | ± 2.5 (Q > 5 l/min) | ||||||||
Response Time | |||||||||
Flow Rate Control | |||||||||
Response time [s] | 0.15, (dAP = 0) | ||||||||
Programmable delay time dS, dr [s] | 0…50 | ||||||||
Switching output damping dAP [s] | 0…5 | ||||||||
Temperature control | |||||||||
Dynamics of response response T05 / T09 [s] | T09 = 20 (Q > 5 l/min ) | ||||||||
Software / Programming | |||||||||
Parameter selection | Flow rate control, flow meter, counter with presetting, Temperature control, hysteresis / window, normally open / normally closed, switching logic, current output / voltage output / pulse output, Start delay, display can be switched off, Display | ||||||||
Interfaces | |||||||||
Communication interface | IO-Link | ||||||||
Transmission method | COM2 (38.4 kBaud) | ||||||||
IO-Link test | 1.1 | ||||||||
SDCI standard | IEC 61131-9 | ||||||||
IO-Link Device ID | 575 / 00 02 3f | ||||||||
Profiles | Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis | ||||||||
SIO mode | yes | ||||||||
Desired port type | A | ||||||||
Analog operating data | 3 | ||||||||
Binary operating data | 2 | ||||||||
Min. cycle time [ms] | 5 | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | -10…60 | ||||||||
Storage temperature [°C] | -25…80 | ||||||||
Degree of protection | IP 67 | ||||||||
Tests / approvals | |||||||||
EMC |
| ||||||||
Impact resistance |
| ||||||||
Vibration resistance |
| ||||||||
MTTF [g Code] | 145 | ||||||||
Pressure Equipment Directive | Good engineering practice, can be used for fluid group 2, group liquids 1 on request | ||||||||
Mechanical data | |||||||||
Weight [g] | 641.5 | ||||||||
Material | stainless steel steel (1.4404 / 316L), PBT-GF20, PC, FKM, TPE medium | stainless steel steel (1.4404 / 316L), PEEK, FKM | |||||||
Process connection | G 1 DN25 threaded connection Flat seal | ||||||||
Displays / Controls | |||||||||
Display |
| ||||||||
Notes | |||||||||
Notes |
| ||||||||
Pack quantity | 1 piece | ||||||||
electrical connection | |||||||||
Connection | Connector: 1 x M12, Contacts: gold-plated | ||||||||
Diagrams and Graphs | |||||||||
Pressure Loss | dP | Pressure loss | Q | volumetric consumption | |