We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Call us to get a great deal on Keyence . We supply only new equipment Keyence directly from the manufacturer, therefore we can offer the best price and a quality guarantee. FAMAGA sells only certified industrial equipment and gives an official guarantee from the producer Keyence.
Our employees speak your language. In a short time they will find for you Keyence at the best value, will select any for you spare parts and accessories for Keyence , will recommend counterparts and agree delivery time to the doors of your company.
Great logistics system allows us to ship equipment to any city in South Africa or any point of the world for the delivery chosen by you in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Fiji, Tonga, Greece, Djibouti, Swaziland, Colombia, Czech Republic, Algeria, Kazakhstan, Egypt, Denmark, Liechtenstein, Albania, Macedonia, Chad, Barbados, Slovenia, Tajikistan, Seychelles, Lebanon, Laos, Kuwait, Bahamas, Switzerland, Dominica, Japan, South Korea, Norway, Equatorial Guinea, Cuba, Ethiopia, Lesotho, Singapore, Malawi, Armenia, Senegal, Uruguay, Mali, Uganda, Burundi, Venezuela, Myanmar, Mauritania, Chile, Guinea, Belarus, Kenya, Saudi Arabia, Malta, San Marino. If you become our constant customer, you will get special, even more attractive terms of cooperation.
Our company has been working in South Africa for over nine years, supplying equipment to over 19000 clients all over the earth. Among our clients are over 2400 famous corporations with world names.
For prices and delivery terms please contact us, E-mail us vendor code or description of needed goods.
Model | LV-N11N | |
Type | 2 output | |
Output | NPN | |
Cable/connector | Cable | |
Main/Expansion unit | Main unit | |
I/O | Control outputs | 2 output |
External input | 1 input | |
Monitor output | None | |
Response time | 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1 | |
Output selection | LIGHT-ON/DARK-ON (switch-selectable) | |
Timer function | Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. | |
Control outputs | NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less | |
Monitor output | - | |
External input | Input time 2 ms (ON)/20 ms (OFF) or more*2 | |
Multiple connections to expansion units | Up to 17 units can be connected in total (two-output type is treated as two units) | |
Protection circuit | Reverse polarity protection, Over-current protection, Surge absorber | |
Number of interference prevention units | Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3 | |
Case size | H 32.6 mm ? W 9.8 mm ? L 78.7 mm | |
Rating | Power voltage | 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS |
Power consumption | Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4 Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4 Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V) *5 | |
Environmental resistance | Ambient temperature | -20 to +55 °C (No freezing)*6 |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 500 m/s2, 3 times in each of the X, Y, and Z directions | |
Material | Cable | PVC |
Case | Main unit and cover material: Polycarbonate | |
Weight | Approx. 75 g | |
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units. |