Sensor FS-V21RP Keyence
Sensor FS-V21RP Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence FS-V21RP

Manufacturer

Keyence

Country

Japan

Name

FS-V21RP

Type

Sensor

Description

FS-V21RP-Verstärker

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications FS-V21RP

Contact us to get a great deal on Keyence . We supply only new industrial machinery Keyence directly from the manufacturer, therefore we can offer the most beneficial price and a quality guarantee. FAMAGA sells only certified products and gives an official guarantee from the manufacturer Keyence.

Our employees speak your language. In a short time they will find for you Keyence at the best value, find your desirable spare parts and accessories for Keyence , will recommend counterparts and agree delivery timings to the doors of your company.

Great shipping geography allows us to deliver industrial machinery to any city in South Africa or any point of the world for the delivery chosen by you in a short time . If you become our constant client, you will get even more attractive terms of delivery.

Our enterprise has been working in South Africa for over eight years, supplying industrial machinery to over 17500 clients around the globe. The list of our clients includes over 2600 large corporations with world names.

If extra information is needed please contact us, E-mail us vendor code or description of needed goods.

Features FS-V21RP

Fibre Amplifier, Cable Type, Main Unit, PNP
Model FS-V21RP
Type Main unit, PNP
Light source Red LED
Response time 250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /500 µs (HIGH RESOLUTION) /50 µs (HIGH SPEED)
Output selection Light-ON/Dark-ON selectable
Indicator lamp Operation indicator: Red LED Dual digital monitor: Dual 7-segment display [Preset Value (4-digit green LED indicator) and Current Value (4-digit red LED indicator) illuminated together. Current Value range: 0 to 65,520, Excess gain: 0 P to 999 P] Hold function: Possible to display both peak and bottom hold values. Bar LED monitor: Possible to display together with Current Value Excess gain displayed (85 to 115 % in 7 steps)
Detection mode Light intensity/rising edge/falling edge
Shift function Max. ±1,999 (variable)
Timer function Mode Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, selectable
Variable range 1 to 500 ms [1 to 30 ms (in 1 ms increments), 30 to 50 ms (in 2 ms increments), 50 to 200 ms (in 10 ms increments), 200 to 500 ms (in 50 ms increments)]
Accuracy ±10 % of the Preset Value
Control output PNP open-collector 100 mA max. (30 VDC max.)*1, Residual voltage: 1 V max.
Rating Power voltage 12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less
Power consumption Normal S-APC OFF: 650 mW max. (27 mA max. at 24 VDC), S-APC ON: 720 mW max. (30 mA max. at 24 VDC)*2
ECO half S-APC OFF: 530 mW max. (22 mA max. at 24 VDC), S-APC ON: 600 mW max. (25 mA max. at 24 VDC)*2
ECO all S-APC OFF: 480 mW max. (20 mA max. at 24 VDC), S-APC ON: 550 mW max. (23 mA max. at 24 VDC)*2
Environmental resistance Ambient light Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.
Ambient temperature -10 to +55 °C (No freezing)*3
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Case material Polycarbonate
Weight Approx. 80 g (including 2-m cable)
*1 20 mA at maximum for the expansion unit. *2 S-APC will be always turned ON when the high-resolution or high-speed mode is selected. S-APC is by default set to OFF in any other mode. *3 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 3 to 10 Units: –10 to +50 °C 11 to 16 Units: –10 to +45 °C