We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Keyence
Country
Japan
Name
FD-Q32C
Type
Process Sensor
Description
anklemmbarer Durchflusssensor 1“ (max. 200 L/min) bzw. 1 ¼“ (max. 300 L/min) 90261021000 CHINA
Stock availability:
On request
Contact us to get a great deal on Keyence . We supply only new machine-tools Keyence directly from the producer, therefore we can offer beneficial price and a quality guarantee. FAMAGA sells only certified products and gives an official guarantee from the producer Keyence.
Our workers speak your language. In a short time they will find for you Keyence at the best value, will select any for you spare parts and accessories for Keyence , will recommend counterparts and agree delivery time to the doors of your company.
Well-functioning logistics system allows us to deliver machine-tools to any city in South Africa or any point of the world for the delivery chosen by you in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Lithuania, Romania, Mongolia, Peru, Israel, Italy, Kiribati, Zambia, Palestine, Bahrain, Liechtenstein, Bangladesh, Cuba, Malaysia, Bahamas, Norway, Seychelles, Malta, Japan, Mauritania, Central African Republic, Ecuador, Turkey, Dominican Republic, Switzerland, Colombia, Barbados, Equatorial Guinea, Honduras, Estonia, New Zealand, Kenya, Philippines, Nepal, Yemen, United Kingdom, Iceland, Canada, Morocco. If you become our constant customer, you will get the best terms of cooperation.
Our company has been working in South Africa for over ten years, supplying machine-tools to over 1700 clients all over the earth. The list of our clients includes over 2400 large corporations with world names.
For extra information please contact us, send your request to our E-mail.
Model | FD-Q32C | |
Supported pipe diameter | 1' (25 A), o28 to o37 (mm) 1 1/4' (32 A), o37 to o44 (mm) | |
Supported pipe materials | Metal pipe/Resin pipe*1 | |
Supported fluids | Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1 | |
Supported fluid temperature | 0 to 85°C (No freezing on the pipe surface)*2 | |
Maximum rated flow | 1' (25 A): 200 L/min 1 1/4' (32 A): 300 L/min | |
Zero cut flow rate | 5 L/min (Default)*3 | |
Display method | Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator | |
Display update cycle | Approx. 3 Hz | |
Display resolution | 0.1/ 1 (Default :1) (L/min) | |
Response time | 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s | |
Repeatability | 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4 (Specific to selected response time)) | |
Hysteresis | Variable | |
Integrated flow unit display | 1/ 10/ 100/ 1000/ 10000 (Default : 1) (L) | |
Integrated flow data storage cycle | Save to memory every 10 seconds | |
Memory backup | EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more) | |
Power I/O connector | M12 4-pin connector | |
Input/Output (Selectable) | Output (ch.1/ch.2) | Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5 |
Analogue output (ch.1/ch.2) | 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 ? or less*5 | |
External input (ch.2) | Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more*5 | |
Power source | Power supply voltage | 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS |
Current consumption | 130 mA or less (Load current excluded)*6 | |
Protection circuit | Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection | |
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) |
Ambient temperature | -10 to +60 °C (No freezing) | |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Shock resistance | 100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | |
Material | Sensor main unit | PPS/PES/PBT/SUS303/SUS304/SUSXM7 |
Sensor surface | Rubber | |
Mounting bracket | SUS304/PA/POM/SUSXM7 | |
Weight | Approx. 530 g (including mounting bracket) | |
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) *2 Contact KEYENCE when the temperature of the pipe is greater than 85°C *3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range. *5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO) *6 When including the loads, please add 200 mA to this value. |