Order Photo on LABOM GA2510-A101-B43-C121300-D2-M22-N2-T11-W2674 — 26.07.2021

Order Photo on LABOM GA2510-A101-B43-C121300-D2-M22-N2-T11-W2674 — 26.07.2021

LABOM GA2510-A101-B43-C121300-D2-M22-N2-T11-W2674 — Shipped 26.07.2021
Send request to sales@famaga.com

Manufacturer

LABOM

Country

Germany

Part number

GA2510-A101-B43-C121300-D2-M22-N2-T11-W2674

Description

GA251 RESISTANCE THERMOMETER Pt 100 with thermowell see data sheet T4-025-2 0 explosion protection: without A10 process connection: G 1/2 B 1 material process connection: stainless steel mat.-no. 1.4571 (316Ti) B43 thermowell length total L: 395 mm C12 thermowell diameter: F1 = 9 mm 1 material thermowell: stainless steel mat.-no. 1.4571 (316Ti) 300 insertion length U1: 300 mm length of measuring insert l5: 405 mm D2 measuring insert: ø 6 mm, rigid M2 tolerance: class A per DIN EN 60751 2 application range: -50...+400°C N2 sensor type: 1 x Pt100, 3-wire technology T11 connection head: model B, cap with 2 slotted screws, IP 54 material: aluminium electrical connection: M20x1.5 cable gland for cable ø 9-14 mm, material nickel-plated brass W2674 EAC-TR certification exemption statement

Order date

26.07.2021

FAMAGA always strives to provide the best prices and timings of supplies for its customers. We sell only original equipment and spare parts, although we are not always the official distributor or manufacturer's dealer. All displayed trademarks and part numbers are the property of their respective owners.

Price: On request

Submit a request

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Description

FAMAGA company managers have successfully taken the order and shipped the order for LABOM GA2510-A101-B43-C121300-D2-M22-N2-T11-W2674 from 26.07.2021 to United States. After sending request, the customer received best quotation and door-to-door delivery from FAMAGA company. Interested in the same product? Send us a request and our managers will help you choose and purchase the items you need of LABOM. To request prices and delivery times, please fill out the feedback form or send a description of the items you need to the email address sales@famaga.com

About the manufacturer

Our company will send you manufacturing equipment of LABOM if it is needed. We already delivered this spare parts and other industrial equipment before. If you need any information please, fill in the feedback form or send a description of goods you need to our e-mail sales@famaga.com">sales@famaga.com

Latest orders FAMAGA

Latest orders LABOM

Description

Vendor code

DL2300-A3007-L22 PRESSURE TRANSMITTER UNIVERSAL for diaphragm seal operation design: standard housing acc. to data sheet D4-029 measuring principle: piezoresistive explosion protection: without measurement: gauge pressure measuring range: 0...4 bar, overload limit 20 bar output signal: 4...20 mA, 2-wire circuit DIAPHRAGM SEAL for food / pharmaceutical / biotechnology design with coupling nut see data sheet D5-025 process connection: DIN 11851, DN 40 / PN 40 connection of meas. instrument directly screwed G 1/2 material wetted parts: stainless steel mat.-no. 1.4435 (316L) system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered design temperature process -10...+140 °C

CC1020-A1056-H1

DL4100-HY-A4007-L23-T61-W1020 DRUCKMESSUMFORMER COMPACT für Druckmittleranbau Bauform: mit Temperaturentkoppler gemäß Datenblatt D4-020-7 Ex-Schutz: ohne Drucksensor: Piezoresistiv für Überdruck Messbereich -1...9 bar, Überlastgrenze 60 bar Messgenauigkeit: Linearitätsfehler incl. Hysterese < + 0,2 % v.E. Abgleichgenauigkeit < +/- 0,2 % v.E. Ausgangssignal: 4...20 mA, 2-Leitertechnik elektrischer Anschluss: Winkelstecker nach DIN EN 175301-803-A (DIN 43650 Form A), IP 65, für Kabel ø 4-10 mm MEMBRAN-DRUCKMITTLER für Food/Pharma/Biotechnik Bauform: mit Clampanschluss gemäß Datenblatt D5-026 Prozessanschluss: nach DIN 32676 Reihe A (metrisch) für Rohre nach EN 10357, DN 25 / PN 25 Hygiene-Ausführung nach EHEDG Doc.8 und ASME BPE SF3 Oberflächenrauheit (messstoffberührte Teile) - Drehteile Ra <= 0,76μm - Membran Ra <= 0,38μm - Schweißnaht Ra <= 0,76μm Messgeräteanschluss: direkt verschweißt Mat. messstoffberührte Teile: Edelstahl W.-Nr. 1.4435 (316L) Systemfüllung: Silikonfreies Synthetiköl FD1 gemäß FDA 21 CFR 178.3570 / H1-registriert Einsatztemperaturbereich -10...+200°C Stempelung für Materialzeugnis nach EN 10204 3.1

CC6020-A1091-H1-T110

GA2700-HY-A1433-C1050-G11-N2-T150-Z53 PA2430-F12-H1 RESISTANCE THERMOMETER MiniTherm for food/pharmaceuticals/biotechnology acc. to data sheet T4-015 measuring resistor: Pt100, tolerances per class A per DIN EN 60751 process connection: clamp connection nominal width: Tri Clamp 1" / 1 1/2", ø 50.5 mm temperature detecting element: ø 6 mm insertion length U1: 50 mm material wetted parts: stainless steel mat.-no. 1.4404 (316L) measuring resistor: 1 x Pt100, 3-wire technology, standard electrical connection: circular connector M12 x 1 (4 pins) incl. transmitter into st. steel plug housing with locking plug M12 (type PA2430) TRANSMITTER for temperature (Pt 100), programmable 0...150 °C error current if there is a sensor break 22.8 mA sensor offset: 0 °C, standard damping: 0 s, standard output signal: 4...20 mA, standard

GA2700-HY

DE1180-A4001-L23-T99-W4999 PRESSURE TRANSMITTER COMPACT for diaphragm seal operation design: with temperature decoupler see data sheet D4-020-7 explosion protection: without pressure sensor piezoresistive for gauge pressure measuring range -1...24 bar, overload limit 60 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s. output signal: 4...20 mA, 2-wire technology electrical connection: right angle plug acc. to DIN EN 175301-803-A (DIN 43650, model A) IP 65, for cable ø 4...10 mm ADDITIONAL DESIGN: see below Design for process temperatures up to 205 ° C - EAC-TR certification exemption statement - metrological certificate for the use in Russian Federation DIAPHRAGM SEAL for general application, screw-in thread see data sheet D5-032 per DIN 3852: G 1/2 A, PN 400 design: standard connection of meas. instrument directly welded material wetted parts: stainless steel mat.-no. 1.4404/1.4435 (316L) system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered DMB_787 temperature range: see below -20...+205°C

CC6020-A1093-H1-T110-W4999-W2675

CV3110 PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 A1 pressure sensor: piezoresistive for gauge pressure 059 nominal range: 0...16 bar, overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F80 measuring range: setting see below lower range value: - 1,000 upper range value: + 15,000 unit: bar H11 output signal: 4...20 mA, rising characteristic (standard) 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without Y4 screw cap with window mat. Macrolon N5 switching module: with 2 floating channels, pluggable, electrically isolated at all sides, switching capacity 30 V DC / 0.5 A 1 switching module setting: at the factory, see below 1. switch contact: switch point: 8 bar breaker hysteresis:0,1% (falling) 2. switch contact: switch point: 10 bar breaker hysteresis:0,1% (falling) T6 case: hygienic design with screw cap material: stainless steel degree of protection: IP 66 incl, vent filter, stainless steel T31 electrical connection: circular connector M 12x1 (8 pin) K1085 design standard W4020 ADDITIONAL DESIGN: marking (adhesive label), see below W2002 CALIBRATION PROTOCOL: with 5 measuring points DL9 DIAPHRAGM SEAL for food/pharmaceutical/biotechnology 016 design: APV flange design HY hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm E1 basic body material: stainless steel (316L) G1 diaphragm material: stainless steel (316L) A400 connection of meas. instrument directly welded L22 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered operating temperature range -10...+140 °C spare parts for fab.-no.: 1819962/10/003

CV3110-A1059-F80-H1100-M1-Y4-N51-T6-T31-K1085-W4020-W2002 DL9016-HY-E1-G1-A400-L22

CK5220-A2057-K2 DL3200-A1007-L22 PRESSURE TRANSMITTER with bourdon tube, safety pattern gauge acc. to data sheet D4-036 safety case: NS 100 per EN 837-S1 case design degree of protection IP 65, with case filling, process connection bottom explosion protection: without process connection: G 1/2 B nominal range: 0...6 bar overload protected: 1.3 times output signal: 4...20 mA, 2-wire technology case filling: Labofin DIAPHRAGM SEAL for food / pharmaceutical / biotechnology design with clamp connection see data sheet D5-026 process connection: per ISO 2852 for pipes per ISO 2037, DN 38 / PN 16 connection of meas. instrument with temperature decoupler A100, screwed G 1/2 material wetted parts: stainless steel mat.-no. 1.4435 (316L) system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered design temperature process -10...+140 °C

CK5220-A2057-K2

CB6 COMPACT PRESSURE TRANSMITTER with threaded connection see data sheet D4-020-1 design: internal diaphragm explosion protection: without pressure sensor: piezoresistive for gauge pressure measuring range see below -1...17 bar, overload limit 60 bar H1 K1010 T110 output signal: 4...20 mA, 2-wire technology process connection: G1/2 B nach DIN 837-1 material wetted parts - sensor diaphragm, stainless steel mat. no. 1.4404/1.4435 (316L) - socket, stainless steel mat. no. 1.4404/1.4435 (316L) electrical connection: right angle plug acc. to DIN EN 175301-803-A (DIN 43650, model A) IP 65, for cable ø 4...10 mm

CB6010-A1999-H1-K1010-T110

PA2200-F12-H1 TEMPERATURE TRANSMITTER head mounted, SIEMENS Sitrans TH200, 2-wire, universal programmable digital transmitter with electrically isolated input / output wire-break and short-circuit monitoring for sensor diagnostic LED for checking sensor and internal device operation test jacks for monitoring the output signal without breaking the current loop explosion protection: without configuration: see below 0...250 °C H1 signal of sensor breakage: 22.8 mA sensor offset: 0 °C damping: 0 s output signal: 4...20 mA; 2-wire circuitry

PA2200-F12-H1

COMPACT PRESSURE TRANSMITTER with threaded connection see data sheet D4-020-1 design: internal diaphragm explosion protection: without pressure sensor: piezoresistive for gauge pressure measuring range 0...25 bar, overload limit 60 bar measuring accuracy: linearity error incl. hysteresis < + 0.2 % f.s. accuracy of adjustment < +/- 0.2 % f.s. output signal: 4...20 mA, 2-wire technology process connection: G1/2 B nach DIN 837-1 material wetted parts - sensor diaphragm, stainless steel mat. no. 1.4404/1.4435 (316L) socket, stainless steel mat. no. 1.4404/1.4435 (316L) electrical connection: right angle plug acc. to DIN EN 175301-803-A (DIN 43650, model A) IP 65, for cable ø 4...10 mm

CB6010-A1060-H1-K1010-T110

PRESSURE AND TEMPERATURE TRANSMITTER COMPACT measuring range: 0...10 bar, overload limit 30 bar, sensor type piezoresistive A1058 K1015 process connection: G 1 A, HYGIENIC, metal-to-metal joint T420 electrical connection: field housing of stainless steel with cable gland H1 pressure output signal: 4...20 mA, 2-wire circuitry temperature sensor: 1 x Pt100 in 3-wire circuitry, class A, for process temperature -20...+80 °C

CE6800

The cities of our deliveries LABOM

Pretoria Johannesburg Cape Town Durban Port Elizabeth Bettiesdam Biesiespoort Boshof Bredasdorp Broederstroom Butterworth Calvert Cape St. Francis Centurion Charl Cilliers Christiana Clarkebury Clifford Coega Coghlan
Show more
Send a request

Our manager will help you find the necessary spare parts and equipment and answer all your questions about our service and delivery terms.

  • Enter your name
  • Enter your contact phone number.
  • This field can not be empty
By clicking "Submit a request", you agree to the Terms of Use and our Privacy Policy