We are not the manufacturer, authorised distributor or authorised representative of the Pepperl+Fuchs brand in South Africa. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Pepperl+Fuchs
Country
Germany
Name
NJ8-18GK-N-150-10M
Part number
106467
Type
Inductive sensor
Description
Inductive sensor NJ8-18GK-N-150-10M
Stock availability:
On request
Call us to get a great deal on Pepperl+Fuchs Inductive sensor NJ8-18GK-N-150-10M 106467. We supply only new gear Pepperl+Fuchs directly from the producer, therefore we can offer the most beneficial price and a quality guarantee. FAMAGA sells only certified industrial equipment and gives an official guarantee from the fabricator Pepperl+Fuchs.
Our highly-qualified workers speak your language. In a short time they will find for you Pepperl+Fuchs Inductive sensor NJ8-18GK-N-150-10M at the best price, find your desirable spare parts and accessories for Pepperl+Fuchs Inductive sensor NJ8-18GK-N-150-10M 106467, will recommend counterparts and agree delivery time to the doors of your company.
Great logistics system allows us to send gear to any city in South Africa or of the world or anywhere you want us to deliver it in a short time South Africa, Botswana, Namibia, Zimbabwe, Mozambique, Madagascar, Bosnia and Herzegovina, Lebanon, Mexico, Nicaragua, Liberia, Morocco, Papua New Guinea, The Bahamas, Eritrea, Peru, Tonga, Lesotho, Japan, Guyana, Greece, Yemen, Benin, Belize, Jordan, Togo, Hungary, Mauritania, Canada, Uganda, Uruguay, Switzerland, Cyprus, Algeria, Georgia, Tunisia, Malaysia, Angola, Laos, Cuba, Philippines, Kyrgyzstan, Equatorial Guinea, Cameroon, The Gambia, Senegal, Turkmenistan, Colombia, Azerbaijan, Brunei, Russia. If you become our constant buyer, you will get the best terms of cooperation.
Our enterprise has been working in South Africa for over nine years, supplying gear to over 18000 clients all over the earth. Among our clients are over 2500 large corporations with world names.
For terms of cooperation please contact us, fill in the form on our website.
General specifications | ||
---|---|---|
Switching function | Normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | 8 mm | |
Installation | non-flush | |
Assured operating distance | 0 ... 6.48 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.3 | |
Reduction factor r304 | 0.85 | |
Output type | 2-wire | |
Nominal ratings | ||
Nominal voltage | 8 V | |
Switching frequency | 0 ... 200 Hz | |
Current consumption | ||
Measuring plate not detected | min. 3 mA | |
Measuring plate detected | &le, 1 mA | |
Compliance with standards and directives | ||
Standard conformity | ||
NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | |
Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 | |
Approvals and certificates | ||
EAC conformity | TR CU 012/2011 | |
UL approval | ||
Ordinary Location | E87056 | |
Hazardous Location | E501628 | |
Control drawing | 116-0452 | |
CSA approval | cCSAus Listed, General Purpose | |
CCC approval | CCC approval / marking not required for products rated &le,36 V | |
Ambient conditions | ||
Ambient temperature | -40 ... 150 °C (-40 ... 302 °F) | |
Mechanical specifications | ||
Connection type | cable SIHF , 10 m | |
Core cross-section | 0.34 mm2 | |
Housing material | PPS | |
Sensing face | PPS | |
Degree of protection | IP65 | |
Cable | ||
Cable diameter | 4.8 mm ± 0.2 mm | |
Bending radius | > 10 x cable diameter | |
Equipment protection level Ga | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Highest permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. | |
Equipment protection level Gb | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 nF , a cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. | |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EU-type examination certificate. | |
Equipment protection level Da | ||
CE marking | [*PD-Z02585A*] | |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. | |
Standards | EN 60079-0:2012+A11:2013, EN 60079-11:2012 Ignition protection Intrinsic safety Use is restricted to the following stated conditions | |
Appropriate type | NJ8-18GK-N-150... | |
Effective internal capacitance | max. 70 µ,F A cable length of 10 m is considered. | |
Effective internal inductance | max. 50 µ,H A cable length of 10 m is considered. | |
General information | ||
Use in the hazardous area | see instruction manuals | |
Category | 1G, 2G |